1. Remove the front cover of the heater (4 screws).
2. Pass the remote controller cord through the wiring
throughway and into the unit.
3. Connect the Y terminals at the end of the remote
controller cord to the terminal block.
4. Secure the remote controller cord with a clamp.
5. Replace the front cover.
Remote controller cord
Remote controller cord
• Use Remote controller cord for any extensions.
• Install according to the National Electrical Code and all applicable local codes.
Connecting Remote Controller Cord to Unit
Keep the remote controller cord away from the freeze prevention heaters in the unit.
Tie the redundant cord outside the water heater. Do not put the extra length inside the equipment.
The remote controller cord can be extended up to 100m with Remote controller cord.
Use a Y type terminal with a resin sleeve. (Without the sleeve, the copper wire may corrode and
cause problems).
Be sure to hand tighten when screwing to the terminal block. Power tools may cause damage to the
terminal block.
Clamp
Terminal Block
Wiring
Throughway
• Applicable Model
Remote Controller
Remote controller
RC-7508M
WHX56, LWHX56
Main
* Up to three remote controllers can be connected. Additional remote controllers cannot be con-
nected by themselves.
The remote controller must be installed in accordance with the installation manual enclosed in the
package.
Cannot be used without a remote controller.
ELECTRICAL WIRING